Noxilizer RTS Series Sterilizers

  • Ultra-low temperature sterilization, 10°C – 30°C.
  • Sterilizes with or without vacuum.
  • Easily and safely installed in-house, in line with production.
  • Process development and validation in accordance with ISO 14937.
  • Robust stainless steel chambers in the range 360 to 16,000 liters.
  • Abator safely removes and disposes of used sterilant.

Questions or inquiries about this?

Contact us for further information.

Call us

Share or add as favorite

Add as favorite

Overview

Getinge, in Partnership with Noxilizer Inc, offers a solution for sterilization in Bio-pharmaceutical, Medical Device and Drug Delivery System Manufacturing. The RTS Series is a range of free-standing sterilizers that use nitrogen dioxide (NO2) gas as sterilant at temperatures in the range from 10°C to 30°C, with or without vacuum. The NO2 Technology from Noxilizer provides a rapid sterilization process, typically in the range 1.5 to 4 hours, which is safe to use in-house, in line with production.

Nitrogen dioxide is a true gas, not a condensing vapor. It is consequently easy to remove during aeration, with minimal, non-cytotoxic residuals. It is effective against a wide range of organisms (data available) and is compatible with a wide range of materials.

The Ultra-low temperature sterilization process is suitable for heat sensitive products that could be damaged by elevated temperatures. By controlling the sterilization process at or around atmospheric pressure (no vacuum), devices that are sensitive to pressure differentials, such as prefilled syringes, can be sterilized without disrupting or moving closures. Use of a vacuum when possible results in a faster process.

The RTS Series sterilizers are designed for routine production, validated in accordance with ISO 14937. They are CE Marked under the Medical Device Directive. One additional model, the Noxilizer Inno2vator, is available for R&D / process development use.

Technical data

Model Width
(mm)
Height
(mm)
Depth
(mm)
Volume
(cu.m)
Chamber Configuration
RTS 360 635 635 915 0,36 Single Door, Cylindrical Chamber.
RTS 400 670 620 1000 0,42 Single or Double Door. Vertical Sliding Door(s).
RTS 800 670 620 2000 0,83 Single or Double Door. Vertical Sliding Door(s).
RTS 1200 800 1200 1300 1,25 Single or Double Horizontal Sliding Door
RTS 1600 1100 1200 1260 1,68 Single or Double Horizontal Sliding Door 1 zone.
RTS 3300 1100 1200 2520 3,35 Single or Double Horizontal Sliding Door 2 zones.
RTS 5000 1250 1600 2520 5,07 Single or Double Horizontal Sliding Door 2 zones.
RTS 7600 1250 1600 3780 7,60 Single or Double Horizontal Sliding Door 3 zones.
RTS 9800 1400 1840 3780 9,79 Single or Double Horizontal Sliding Door 3, zones.

RTS 13000

1400 1840 5040 13,05

Single or Double Horizontal Sliding Door 4 zones.

RTS 16000 1400 1840 6300 16,31 Single or Double Horizontal Sliding Door 5 zones.

Accessories

Loading Equipment

Loading Systems are available to product and production needs

Consumables

  • Chemical indicators
  • Biological indicators
  • Process Challenge Devices (PCD)
  • Sterilant
  • Scrubber material

Applications

Terminal Sterilization

Noxilizer RTS Series sterilizers are used for Terminal Sterilization of Medical Devices and Drug Delivery devices. Read more about Terminal Sterilization.

Component and Equipment Processing

They may also be used for the sterilization of components and equipment used in bio-pharmaceutical production. Read more about Component and Equipment Processing.