Select region
Submit

Getinge Lancer LSS Laboratory Steam Sterilizers

Getinge Lancer LSS Laboratory steam sterilizers offer high-performance autoclaving of labware, process materials, and byproducts used in laboratory applications.

Lancer LSS 275
Lancer LSS 450
Lancer LSS 130

Meeting space and budget requirements for laboratories where sterile labware is essential.

The Getinge Lancer LSS autoclaves are preprogrammed with standard gravity, vacuum, and liquid cycles. This ensures reliable sterilization of the most common loads in laboratory applications. All cycle phases are automatically sequenced, monitored and documented by the control system to ensure that the cycle has performed according to pre-set parameters. Choose from four models to meet your space and capacity requirements.

Lancer LSS Cycles

Gravity cycles

Gravity cycles are typically used for sterilization of hard goods such as glassware. They use steam to remove the air from the chamber. 

Lancer LSS Cycles

Vacuum cycles

Vacuum cycles are suitable for sterilization of porous goods such as filters. A vacuum sequence quickly removes the air from the chamber, including ambient air trapped within the load. 

Lancer LSS Cycles

Liquid cycles

These cycles are selected for sterilization of liquids in open containers. The cycles slow the rate of exhaust to prevent boil-over.

Door gasket for safe and reliable steam sterilization

The door gasket closes around the door face to automatically seal the autoclave chamber when steam pressure is applied. This minimizes the risk of air leaking into the chamber, which could jeopardize the sterilization result.  In the unlikely event of a door failure, the gasket is designed to relieve pressure. Baffles at the autoclave chamber opening safely direct steam away from the operator.

Minimal footprint with vertical sliding door

In manual door configurations, the door is counterbalanced and requires minimal operator force to open and close. The door operates in a downward motion and vanishes within the front cabinet; no headspace or additional floor space are required, which minimizes the sterilizer’s footprint.

Water saver system

When installing the new improved water saver system, sustainability objectives can be achieved. The system incorporates a recirculation system, a circulation pump, temperature control and possibility to connect to a building circulating chilled water system. The water consumption can be reduced by up to 95%, depending on load and cycle selection, without affecting the sterilization performance.

Lancer LSS 130

The standard LSS 130 configuration features a 4.6 cu.ft. (130 L) chamber with a single door and two extendable shelves. Recessed one-wall installation is standard, but optional freestanding installation is available for single door configurations.

  Single door (standard) Double door (option)

Chamber dimensions (WxHxD)

17,5“ x 17,5“ x 26“ (445 x 445 x 660 mm)

17,5“ x 17,5“ x 26“ (445 x 445 x 660 mm)

Exterior dimensions (WxHxD)

26,25“ x 74“ x 36,125“ (667 x 1880 x 918 mm)

26,25“ x 74“ x 38,25“ (667 x 1880 x 972 mm)

Chamber volume

4,6 cu.ft. (130 L)

4,6 cu.ft. (130 L)

Door operation

Manual: Standard
Automatic: Option

Manual: Standard
Automatic: Option

Installation

Freestanding: Option
Recessedone-wall: Standard
Recessed two-wall: N/A

Freestanding: N/A
Recessed one-wall: Standard
Recessed two-wall:N/A

Loading equipment

Interior rack two shelves: Standard
Extrashelf: Option
Load car: N/A
Transfer trolley: NA

Interior rack two shelves: Standard
Extrashelf: Option
Load car: N/A
Transfer trolley: NA

Lancer LSS 275

The LSS 275 has a chamber volume of 9.7 cu. ft. (275 L) in a single-door design with two extendable shelves. The standard configuration can be freestanding or recessed in one wall. An optional double door pass-through configuration can be recessed in one- or two-wall arrangements. Optional load cars and transfer trolleys increase loading options and provide ergonomic improvements for operators. 

  Single door (standard) Double door (option)

Chamber dimensions (WxHxD)

21" ×21" ×38" (532 ×532 ×965 mm)

21" ×21" ×38" (532 ×532 ×965 mm)

Exterior dimensions (WxHxD)

30" ×74" ×48.125" (762 ×1880 ×1222 mm)

30" ×74" ×50.25" (762 ×1880 ×1276 mm)

Chamber volume

9.7 cu. ft. (275 L)

9.7 cu. ft. (275 L)

Door operation

Manual : Standard
Automatic: Option

Manual : Standard
Automatic: Option

Installation

Freestanding: Option
Recessedone-wall: Standard
Recessed two-wall: N/A

Freestanding: N/A
Recessed one-wall: Option
Recessed two-wall: Standard

Loading equipment

Interior rack two shelves: Standard
Extrashelf: Option
Load car: Option
Transfer trolley: Option

Interior rack two shelves: Standard
Extrashelf: Option
Load car: Option
Transfer trolley: Option

Lancer LSS 490

The LSS 450 provides a chamber volume of 15.8 cu. ft. (447 L) and is equipped with two extendable shelves. An optional load car and transfer trolley can be selected to increase loading possibilities and improve ergonomics. The LSS 450 is available in single or optional double-door configurations. 

 

Single door (standard)

Double door (option)

Chamber dimensions (WxHxD)

26.5" ×26.5" ×39" (672 ×672 ×1000 mm)

26.5" ×26.5" ×39" (672 ×672 ×1000 mm)

Exterior dimensions (WxHxD)

39.5" ×74" ×51.9" (1003 ×1880 ×1318 mm)

39.5" ×74" ×52.7" (1003 ×1880 ×1339 mm)

Chamber volume

15.8 cu. ft. (447 L)

15.8 cu. ft. (447 L)

Door operation

Manual : N/A
Automatic: Standard

Manual : N/A
Automatic: Standard

Installation

Freestanding: Option
Recessed one-wall: Standard
Recessed two-wall: N/A

Freestanding: N/A
Recessed one-wall: Option
Recessedtwo-wall: Standard

Loading equipment

Interior rack two shelves: Standard
Extrashelf: Option
Load car: Option
Transfer trolley: Option

Interior rack two shelves: Standard
Extrashelf: Option
Load car: Option
Transfer trolley: Option

Lancer LSS 490

The LSS 590 offers a chamber volume of 20.7 cu. ft. (586 L) and is available in single or double door configurations. The single door configuration is recessed in one wall as standard, but a freestanding option is available. The standard double door configuration is recessed in two walls, but can but can be installed in a one-wall arrangement as well.

 

Single door (standard)

Double door (option)

Chamber dimensions (WxHxD)

26.5" ×26.5" ×51" (672 ×672 ×1300 mm)

26.5" ×26.5" ×51" (672 ×672 ×1300 mm)

Exterior dimensions (WxHxD)

39.5" ×74" ×63.9" (1003 ×1880 ×1623 mm)

39.5" ×74" ×64.7" (1003 ×1880 ×1643 mm)

Chamber volume

20.7 cu. ft. (586 L)

20.7 cu. ft. (586 L)

Door operation

Manual : N/A
Automatic: Standard

Manual : N/A
Automatic: Standard

Installation

Freestanding: Option
Recessedone-wall: Standard
Recessed two-wall: N/A

Freestanding: N/A
Recessed one-wall: Option
Recessed two-wall: Standard

Loading equipment

Interior rack two shelves: N/A
Extra shelf: N/A
Load car: Option
Transfer trolley: Option

Interior rack two shelves: N/A
Extra shelf: N/A
Load car: Option
Transfer trolley: Option