Intergard Woven Aortic Arch and Hemabridge

Intergard Woven Aortic Arch
Hemabridge

Intergard Woven Aortic Arch and Hemabridge

Woven Vascular Grafts

Collagen-coated external-velour polyester graft. 
Water permeability: < 5ml/cm²/min[1]

Overview

Intergard Woven Aortic Arch properties

  • Pre-sewn branches designed for total replacement of all diseased segments, reducing cardiac ischemic time [2],[3],[4]
  • Anatomically correct angle of branches is designed for easy suturing to the host vessels and to prevent graft kinking [4],[5]
  • 30cm length perfusion branch is designed for easy manipulation about the operative site [2],[3],[4]

Intergard Hemabridge properties

  • Designed to allow an easier and less time consuming technique
  • Pre-sewn perfusion branch allows for selective antegrade arterial perfusion[4].

Aortic Arch                                                                                

Diameter Length Reference 
20 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2010080810/1
22 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm   HEWAA2210080810/1
24 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2410080810/1
26 mm x 10 mm x 8 mm x 8 mm x 10 mm  50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2610080810/1
28 mm x 10 mm x 8 mm x 8 mm x 10 mm  50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA2810080810/1
30 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA3010080810/1
32 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA3210080810/1
34 mm x 10 mm x 8 mm x 8 mm x 10 mm   50 cm x 30 cm x 30 cm x 30 cm x 30 cm  HEWAA3410080810/1

Intergard Hemabridge  

Diameter Length Reference 
20 mm x 10 mm  35 cm x 40 cm  HEW2010BRIDGE
22 mm x 10 mm   35 cm x 40 cm HEW2210BRIDGE
24 mm x 10 mm  35 cm x 40 cm  HEW2410BRIDGE
26 mm x 10 mm 35 cm x 40 cm  HEW2610BRIDGE
28 mm x 10 mm 35 cm x 40 cm  HEW2810BRIDGE
30 mm x 10 mm  35 cm x 40 cm  HEW3010BRIDGE
32 mm x 10 mm  35 cm x 40 cm   HEW3210BRIDGE
34 mm x 10 mm  35 cm x 40 cm  HEW3410BRIDGE
36 mmx10 mm  35 cm x 40 cm  HEW3610BRIDGE

Alla referenser

  1. 1. Data on file

  2. 2. Sakamoto, S., et al., Clinical results of aortic arch replacement using a four branched prosthetic graft. J Cardiovasc Surg (Torino), 2003. 44(6): p. 751-5.

  3. 3. Bednarkiewicz, M., et al., Aortic arch replacement using a four-branched aortic arch graft. Eur J Cardiothorac Surg, 2002. 21(1): p. 89-91.

  4. 4. Kazui, T., Total arch replacement with separated graft technique and selective antegrade cerebral perfusion. Ann Cardiothorac Surg, 2013. 2(3): p. 353-7.

  5. 5. Kazui, T., et al. (2001) Use of aortic arch branched graft in the treatment of aortic arch aneurysm or aortic dissection. [Intervascular PN20125/1]