Bölge seçiniz
Gönder

Flow-e Anesthesia Machine

Our extended anesthesia model for a streamlined workflow

Flow-e is our extended and flexible anesthesia machine for a dynamic anesthesia delivery. An extended workstation with a larger worktop, extra storage space, and generous mounting possibilities for auxiliary equipment.

Dynamic Anesthesia Delivery - Every. Breath. Counts. 

Getinge Flow-e anesthesia machine is our extended model for a streamlined workflow in the OR
Flow-e is Getinge's extended anesthesia machine that ensures efficient ventilation performance and personalized care in the OR.
Getinge Flow-e anesthesia machine is our extended model with a larger worktop and more storage space

Extended functionality in the OR

Flow-e delivers personalized anesthesia for a wide range of patients suitable for complex cases as well as general procedures.

  • Ventilation performance to ICU standards
  • Safe low-flow anesthesia with Automatic Gas Control
  • MAC Brain for improved control of depth of anesthesia
  • Active hypoxia prevention with O2Guard
  • Lung Recruitment Maneuvers to prevent postoperative complications

Our unique anesthesia technology makes the difference

 

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. With simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1][2][3][4][5][6]

 

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter atelectasis, to improve oxygenation and help prevent postoperative complications. What once was considered complex and time consuming is now seamlessly integrated into your workflow. [11] [12]

User-friendly anesthesia machine in the OR

 

4 drawers

One large and three smaller

Well-designed drawers take care of your space and storage needs. Slots for spare vaporizers and an optional lockable compartment

 

278 cm rails

For flexible mounting

An unmatched length of stepless rails enabling you to add all the monitors and accessories you need.

Yasal Uyarı

Ürünler, Flow Ailesi anestezi sistemlerinin mevcudiyeti ve SW versiyonu ülkenizde pazarlanmak üzere düzenleyici onayları bekliyor olabilir. Daha fazla bilgi için Getinge temsilcinizle görüşün. Hekim tarafından belirtilen iddialar kesinlikle hekime aittir ve Getinge'nin görüşlerini yansıtmayabilir.
Yasal Üretici · Maquet Critical Care AB · Röntgenvägen 2 SE-171 54 Solna · İsveç · +46 (0)10 335 73 00

Our unique anesthesia technology makes the difference

AGC Anesthesia Flow

Automatic Gas Control (AGC)

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. It is an option uniquely available with Flow-i machines. Automation eliminates the need of continuous manual adjustments: with simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1] [2] [3] [4] [5] [6]

o2guard anesthesia flow

O₂Guard

Active hypoxia prevention

Our O2Guard is the world’s only system for active hypoxia prevention. Should the inspired oxygen level drop below 21%, the O2Guard automatically overrules the settings and increases the flow of oxygen. [7]

Mac brain anesthesia flow

MAC Brain

Better anesthetic agent dosing

For more precise control of depth of anesthesia, we created MAC Brain. A unique tool that visualizes the difference in agent concentration between the lungs and the target organ, the brain. [8] [9] [10]

Lung recruitment flow anesthesia

Lung recruitment

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter
atelectasis, to improve oxygenation and help prevent postoperative complications. [11] [12]

Ventilation anesthesia flow

Ventilation performance

To ICU standards

Innovative Flow Core Technology is designed to promote efficient agent usage, providing the power and precision to ventilate even the most challenging patients. [13] [14] [15]

User-friendly anesthesia machine in the OR

Developed together with clinicians, the extended Flow-e anesthesia machine is designed to facilitate a great scope for configuration and patient safety. With an intuitive interface and emphasis on ease of use [16], our anesthesia solutions ensure a streamlined workflow and efficiency in the operating room that offers enhanced cost control and resource management.

Our anesthesia workstation

Our anesthesia workstation

1. Open platform

Customized to match your needs

2. USB ports and LED light

USB ports for data transfer and power supply are easily accessible. Three step dimmable LED lights up the workspace.

3. Intuitive control panel

A flexibel touchscreen, with quick access presets, gives you one point of control for all functions. 15%u201D tiltable and rotatable touch screen.

Read more
4. Auxiliary O2 and suction

5. Water trap

Visible and accessible

6. Snap on hooks

For convenient placement of tubes, manual breathing bags, suction tips and other accessories.

7. CO2 absorber

Easy to change

8. Large and flexible workspaces

Practical for your everyday needs

9. Electronic vaporizers in double slots

Precise and cost-efficient

Read more
10. 278 cm multipurpose rails

Extensive and flexible mounting options with 5 multipurpose rails

Read more
11. Large drawers

Well-designed drawers take care of your space and storage needs. - Integrated slots for spare vaporizers - Soft close drawer - Lockable compartment (optional)

Read more
12. Central 4-wheel brake and cable pushers

Enhances device mobility

13. Smart cable and hose management

Less clutter, easier cleaning and improved mobility

Kapsamlı Servis ve Destek

 

Prosedürleri iptal etmekten kaçının

Bağlanın ve kontrolü elinize alın

Getinge Online web portalı sizi herhangi bir Getinge cihazına bağlayarak biyomedikal ve klinisyenleri günlük işlerinde destekleyecek değerli verilere erişim sağlar. Portal, hastane kaynaklarınızın çalışma süresini ve verimli kullanımını artırmak için güçlü bir araçtır. 

  • Ameliyathanenizde çalışma süresini artırın
  • Maliyetleri ve karbon ayak izini azaltın
Man looking straight smiling

Tutarlı bir teklif

Getinge Hizmetleri, çalışma süresini ve yatırımınızın uzun vadeli değerini en üst düzeye çıkaracaktır. Sertifikalı saha temsilcilerimiz tarafından proaktif bakım, kolay sorun giderme ve hızlı servis içeren bir servis planı sunuyoruz - ekipmanınızın her zaman tam potansiyeliyle çalışmasını sağlıyoruz.

Anesthesia consumables

Kaliteli sarf malzemeleri

Orijinal Getinge sarf malzemeleri portföyü, mümkün olan en yüksek hasta güvenliği ve kullanım kolaylığı için özel olarak geliştirilmiştir. Orijinal aksesuarlarımız ve sarf malzemelerimiz, Flow Ailesi anestezi uygulama sistemi için en iyi performansı ve güvenliği sağlar.

MSync

Cihazlar arasındaki bağlanabilirlik

MSync, Flow makinesini üçüncü taraf sisteme ihtiyaç duymadan hasta monitörü, HIS ve hasta veri yönetim sistemine bağlamayı kolaylaştırır. Hasta verileri, karar vermeyi desteklemek için gerçek zamanlı olarak HL7 (MSync) aracılığıyla aktarılır.

  • The Getinge Online web portal connects you to any Getinge device, getting access to valuable data that will support biomeds and clinicians in their daily work.

Visit our Academy – training and education designed to enhance your proficiency

For more information about onsite events or remote trainings, you can also contact your local sales & service representative.

  1. 1. Carette R, De Wolf AM, Hendrickx JF. Automated gas control with the Maquet Flow-i. J Clin Monit Comput. 2016 Jun;30(3):341-6.

  2. 2. Getinge case story MX-7418, rev01: Agent savings with Flow-i AGC at Maria Middelare hospital, Belgium.

  3. 3. Lucangelo U, Garufi G, Marras E, et al. End-tidal versus manually-controlled low-flow anaesthesia. J Clin Monit Comput. 2014; 28: 117-121.

  4. 4. Brattwall M, Warrén-Stomberg M, Hesselvik F, Jakobsson J. Brief review: Theory and practice of minimal fresh gas flow anesthesia. Can J Anaesth. 2012 Aug;59(8):785-97

  5. 5. M. Bilgi, S. Goksu, A. Mizrak, et al. Comparison of the effects of low-flow and high-flow inhalational anaesthesia with nitrous oxide and desflurane on mucociliary activity and pulmonary function tests, Eur J Anaesthesiol 2011;28:279–283

  6. 6. Kalmar A. et al. Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment. J Clin Monit Comput. 2022 Jan 3. doi: 10.1007/s10877-021-00803-z.

  7. 7. Ghijselings IE, De Cooman S, Carette R, et al. Performance of an active inspired hypoxic guard. J Clin Monit Comput. 2016 Feb;30(1):63-8t.

  8. 8. Drews FA, Syroid N, Agutter J, Strayer DL, Westenskow DR. Drug delivery as control task: improving performance in common anesthetic task. Hum Factors 2006;48:85–94.

  9. 9. ECRI. The MAC Brain feature on Getinge anesthesia units: ECRI's view. Device Evaluation 2022 Jan5.

  10. 10. Internal report EVU-197031 - 01 - Flow 4.7 Enhanced Post Market Surveillance Report 2019

  11. 11. García-Fernández J, Romero A, Blanco A, et al. Recruitment manoeuvres in anaesthesia: How many more excuses are there not to use them? Rev Esp Anestesiol Reanim.2018 Apr;65(4):209-217

  12. 12. Yassen et al. Respiratory and Hemodynamic Effects of Prophylactic Alveolar Recruitment During Liver Transplant. Experimental and Clinical Transplantation (2021) DOı: 10.6002/ect.2020.0412

  13. 13. Internal test reports comparing Flow-i with vendor machines; EVU 125310, EVU-125312, EVU-125313

  14. 14. Case study contributed by Dr. Waltraud Bruchelt and Dr. Günter Baumann, Dept. of Anaesthesiology and Intensive Care Medicine, University Hospital Graz, Austria.

  15. 15. Lucangelo U, Ajčević M, Accardo A, et al. Flow-i ventilator performance in the presence of a circle system leak. J Clin Monit Comput. 2017 Apr;31(2):273 280.

  16. 16. Internal report EVU 205592 NPS Summary Anesthesia 2019