Seleccione la región
Envíe

Mega 7,5 y 8 fr Catéteres IAB

La familia Mega IAB ofrece la gama más amplia de balones de gran volumen para pacientes de <5' a >6' en comparación con cualquier familia de balones de la competencia. Los CIA MEGA de mayor volumen ofrecen una terapia de CBIA de mayor eficacia con hemodinámica mejorada en comparación con los balones de tamaño convencional para pacientes adultos, como se observa en el gasto cardíaco, PCWP y SVO2, lo que ofrece una mayor eficacia clínica

Mega inta-aortic balloon catheter offers increased augementation for patients of all heights in need of hemodynamic support

Abstract
We report the enhanced augmentation of cardiac output in a 60-year-old man who underwent percutaneous coronary intervention with drug-eluting stent implantation for a large anteroseptal ST-segment-elevation myocardial infarction. Because of persistent systemic hypotension during the procedure, a 50 cc, 8 Fr. MEGA® intra-aortic balloon was inserted, used for 24 hours, and removed without complications. The use of this new balloon — with larger blood volume displacement but smaller caliber at the insertion site — significantly increased cardiac output in 1:1, 1:2, and 1:3 assist modes, by more than 15%, 9%, and 4%, respectively. These findings exceed the average augmentations reported for smaller-volume balloon catheters.

Abstract
A primary cause of adverse outcomes among high-risk patients undergoing percutaneous coronary intervention (PCI) may be a diminished capacity to tolerate the hemodynamic and ischemic insults that can occur during the procedure. A common means of mechanical support during PCI has been the intra-aortic balloon pump (IABP). We describe successful periprocedural mechanical support with a new, 50 cc IABP in a patient with both severe left ventricular dysfunction and extensive coronary arteriosclerosis, for whom PCI with stenting was indicated. The prophylactic use of this 50 cc IABP, which traditionally would be contraindicated because of the patient's height (162.6 cm), markedly increased the diastolic aortic pressure (by ~110 mmHg) over the baseline level, while promptly reducing left-sided heart pressures. This finding appears to exceed the average diastolic augmentation reported for smaller-volume balloons. Although the role of the IABP in high-risk PCI remains controversial, further research is warranted to clarify and compare this new 50 cc IABP to smaller-volume balloons, and ascertain whether the observed hemodynamic benefits can translate into improved clinical outcomes among patients requiring mechanical support during PCI.

Productos relacionados

Mejore su conocimiento gracias a nuestros cursos de formación y formación electrónica

En el Getinge Educational Institute, disponemos de material especializado para temas relacionados con los cuidados intensivos, los procedimientos cardiovasculares, el quirófano y el procesamiento de esterilizaciones. Podemos apoyarle con información sobre las tecnologías actuales y las mejores prácticas para impulsar su rendimiento y productividad.

Para obtener más información sobre nuestros eventos in situ o cursos de formación a distancia, también puede ponerse en contacto con su representante local de ventas y servicio.