Select region

Krohne FLEXMAG 4050C

Single-use electromagnetic flowmeter for bioprocessing 

Distributor Line: As part of HPNE’s partner portfolio, this product extends our ability to deliver complete and reliable bioprocessing solutions under Getinge.

 

KROHNE FLEXMAG 4050 Single-Use Electromagnetic Flow Sensor for biopharma.
The KROHNE FLEXMAG 4050 Electromagnetic Flow Sensor, pictured with disposable, gamma-sterilizable flow tube.

The first electromagnetic flowmeter

The Khrone FLEXMAG 4050 C electromagnetic flowmeter features a disposable flow tube, designed specifically for single-use biopharmaceutical applications like filtration, chromatography, or buffer and media preparation. Produced in a clean room facility, this biocompatible and gamma sterilizable flow tube features a standard single barb fitting, ensuring simple and compliant adaptation to existing single-use systems. The flowmeter additionally delivers a completely stable, direct, and accurate volumetric flow measure that will not drift over time and remains unaffected by fluid properties such as color or density.

Related products

Operational design

  • Disposable flow tube 
  • Factory calibrated, no recalibration needed 
  • No maintenance required
  • Full bore design, low pressure loss 
  • Pulse and current output 

Measurement performance

One transmitter fits 2 flow tubes diameters:

  • ¼" ID: 0.015...3 l/min
  • ⅜" ID: 0.07...14 l/min
  • ½" ID: 0.1...20 l/min
  • Or: ¾" ID: 0.3...62 l/min
  • 1" ID: 0.5...75 l/min
    (extended measuring ranges on request)

Accuracy: ± 1% of measured value, +1 mm/s

Biopharma compliance

  • Wetted parts of the transmitter are manufactured in an ISO 13485 certified site, with production taking place in an ISO 7 cleanroom environment
  • Wetted materials meet USP Class VI / ISO 10993 requirements and are BSE/TSE free compliant
  • Single-use flow path tubes are guaranteed gamma sterilizable at a 25 - 40 kGy irradiation, and are tested up to 50 kGy
  • Each tube is individually packed in a double-layered PA/PE pouch to maintain sterility

Technical data

Materials

 

Transmitter housing  Polycarbonate/Acrylonitrile butadiene styrene (PC/ABS)
Flow tube Manufactured in cleanroom at ISO 13485 certified site. Packed in individual double sealed packing material (pouches)
Wetted materials flow tube  Thermoplastic: Polysulfone (UDEL 1700)
Material of flow tube pouches  Polyamide/Polyethylene (PA/PE)
Measuring electrodes  Hastelloy C22
Earthing electrodes Hastelloy C22
Sterilization of flow tube outside of the original pouch Gamma sterilizable up to 50 kGy and autoclavable up to 121°C for 30 min

 

 

 

 

Process connections

 
Single barb 1/4", 3/8", 1/2", 3/4" or 1" ID.

 

 

 

 

Electrical connections

 
Mains  
Power supply For pulse output: 24 VDC ± 25% (18...30 VDC)
For current output: 24 VDC ± 1%
Power consumption ≤ 3 W
Cable connections Standard; 1 x M12, 8-pin connector
Outputs  
General All operating data are preset at the factory
Pulse output Pulse/frequency output active
¼": 0...10000 Hz; 10000 Hz at Qmax (up to 120%) 3 /8"...1": 0...1000 Hz; 1000 Hz at Qmax (up to 120%)
Pulse width value (at full scale)  Pulse width = symmetrical, 1:1
Active operation  U0 nom = 24 V
Current output Current (active)
4...20 mA; 4 mA at 0 litre per minute; 20 mA at Qmax

 

Life sciences, biopharmaceutical industry

  • Diafiltration
  • Tangential Flow Filtration (TFF)
  • Virus Filtration
  • Harvesting
  • Fill and Finish
  • Perfusion
  • Nano Filtration
  • Chromatography
  • Sterile Filtration
  • Research