Top 3 Causes of Cross Contamination in Biosafety Facilities

Top 3 Causes of
Cross Contamination in Biosafety Facilities

Topics

Top 3 Causes of Cross Contamination 
in Biosafety Facilities

The recent string of incidents within CDC laboratories involving the accidental transfer of live anthrax into a lower level of containment highlights the importance of proper safety practices and well maintained equipment. Unlike cross contamination in other laboratories, which typically only leads to false-positives in scientific tests, contamination in BSL-3 or BSL-4 facilities has the potential to lead to a life-threatening epidemic.

Standard risk assessments have identified three main types of cross contamination that are specific to BSL-3 and BSL-4 facilities.

  • Process interruption
  • Seal leaks
  • Improper material transfers

Understanding the potential for breach during common laboratory procedures can help facility managers more effectively guard against cross contamination in the BSL-3 and BSL-4 environment.

What Causes Contamination?

Many BSL-3 and BSL-4 facilities use autoclaves to decontaminate various research materials before disposal or transfer from one containment area to another.
Two common problems arise in facilities that have outdated or improperly maintained autoclave equipment. These problems can work in tandem with the main cause of cross contamination within biosafety facilities: material transfer.

1. Faulty Equipment: Process Interruption

Process interruption is one of the most common ways cross contamination can occur. If the autoclave cycle is not completed successfully or is insufficient for complete decontamination of the potential agents, then live strains may be allowed to transfer between areas of containment. This type of cross contamination is typically due to faulty or improperly maintained equipment. Cross contamination can also occur if autoclaves are not properly specified at installation. To meet decontamination needs for specific applications and compliance, autoclaves must meet the necessary criteria.

2. Improper Equipment: Seal Leaks

A second common area for cross contamination is a leaking seal. BSL-4 facilities are required to incorporate an integrated bioseal with their pass-through autoclaves. If this seal is insufficient for the materials being handled or has a leak, cross contamination between containment areas is possible.

3. The Main Issue: Material Transfers

Material transfers are by far the most common cause of cross contamination in biosafety facilities. Properly designed autoclaves in pass-through configurations have door interlocks which ensure proper material flow, allowing only a single door to be opened at a time and only after the complete decontamination cycle has taken place. If a faulty or outdated autoclave allows both doors to be opened at once, direct cross contamination between the two areas of containment is possible.

The Solution

When it comes to reducing the chance of cross contamination in biosafety facilities, knowing what to look for in an autoclave is an important factor. A recent whitepaper provides a detailed look at incorporating autoclaves into BSL-3 and BSL-4 facilities to improve biosafety.

Related articles

  • Research Laboratories

Bioreactor preparation solutions

An automated, preprogrammed cleaning process employs best practices for cleaning the multi-use bioreactor. This allows you to validate your cleaning process and ensure that your bioreactor is ready for sterilization.

Læs mere

  • Research Laboratories

Best Practices for Multi-Use Bioreactor Sterilization

Regardless of whether the bioreactor is being prepared for a same-use application or an entirely different one, all bioreactor components, as well as liquid media, must be made ready through an effective and reproducible process.

Læs mere

  • Research Laboratories

The 4 Pillars of Successful Labware Cleaning

Clean labware is a critical component in any laboratory because contaminated labware can lead to false test results and expensive re-testing.

Learn more

  • Research Laboratories

5 Factors for Safe Material Transfer in BSL-3 and BSL-4 Facilities

BSL-3 and BSL-4 laboratories highlight the fact that if proper protocols are not followed, contamination can cause detrimental results.

Learn more

  • Research Laboratories

An automated bioreactor solution tailored for the next generation of science

At the Delft University of Technology in the Netherlands, professors and PhD students needed a new solution for evolutionary engineering – to improve the study of genetically engineered cells in the pursuit of replacing more petrochemicals with plant-based materials. This called for a robust, flexible, and automated bioreactor setup tailored to meet the specific challenges related to evolution studies.

Læs mere