Pack Release

503-width460.jpg
getinge-assured-emulating-indicator-4-400px-width460.jpg
getinge-green-tape-steam-400x320px-width460.jpg

Pack Release

When a pack is opened, the OR staff can quickly verify that the conditions for sterilization were achieved and that the instruments and utensils are safe to use in surgical procedures.

Overview

Indicators for monitoring the specific sterilization parameters of time, temperature and – depending on sterilization method – steam, Formaldehyde, Ethylene Oxide and relative humidity inside the pack.

Product Ranges

Pack Release for Steam

Tape Steam

Tape for sterilization packages.

Overview

The Getinge Assured Tape (Steam) can be used in 121°C gravity sterilizers and 132-134°C pre-vacuum sterilizers.

Stripes turn dark brown/black after exposure to steam or chemical vapour sterilization conditions, thus providing identification of processed items.

* Not available for sales in the USA.

Tape for sterilization packages

Two widths, 18 mm and 24 mm

Color change from white to brown/black

EN ISO 11140-1, Type 1

Technical data

Packaging
  Order No
Tape 18mm Steam, 48 rolls per box 504053200
Tape 24mm Steam, 36 rolls per box 504053300

Green Tape Steam

Color change from green to black.

Overview

The Getinge Assured Green Tape (Steam) can be used in 121°C gravity sterilizers and 132-135°C pre-vacuum sterilizers.

Stripes turn black after exposure to steam sterilization conditions, thus providing identification of processed items.

* Not available for sales in the USA.

Tape for sterilization packages

Enviromental friendly

Green tape does not contain lead

Two widths, 18 mm and 24 mm

Color change from green to black

Consistent with EN ISO 11140-1, Type 1

Technical data

Packaging
  Order No
Green Tape 18mm Steam, 48 rolls per box 6001154902
Green Tape 24mm Steam, 36 rolls per box 6001154903

Multicritical Process Variable Indicator Steam

Conforms to EN ISO 11140-1 Type 4.

Overview

The Getinge Assured Multicritical Process Variable Indicator (Steam) is designed to be used in steam sterilizers operating at 132 to 134°C and 121°C. When used as directed, Multicritical Process Variable Indicator (Steam) gives a visible indication that sterilizing parameters (time, temperature and steam) were met according to EN ISO 11140-1.

* Not available for sales in the USA.

Conforms to EN ISO 11140-1 Type 4

Laminated (short) and Unlaminated (long)

Clear color change from white to black

Assurance to the user that minimum cycle parameters have been achieved inside the pack

Can be used as a permanent record

Cost effective

Technical data

Packaging
  Order No
Multicritical Process Variable indicator, short, L: 101 mm, laminated, 250 pcs per case 504051700
Multicritical Process Variable indicator, long, L: 195 mm, unlaminated, 250 pcs per case 504051800

Emulating Indicator (Strip) Steam

Clear color change from purple to green.

Overview

The OR staff is responsible for maintaining the integrity of the sterile field. Getinge Assured Emulating Indicators (Type 6) are the most advanced chemical indicators for monitoring the specific steam sterilization parameters of time, temperature and steam inside the pack and assures the user that maximum values for all cycle parameters have been achieved.

Our Type 6 indicators have the highest precision available and require a full steam sterilization cycle to change color.

When a pack is opened, your OR staff can quickly verify that the conditions for sterilization were achieved and that the instruments and utensils are safe to use in surgical procedures.

* Not available for sales in the USA.

Clear color change from purple to green

Superior diagnostic ink technology

Lead free and no toxic heavy metals

Can be used as a permanent record

Consistent with EN ISO 11140-1 Type 6

Cycle specific calibrations – 134°C at 4, 5.3, 7 and 18 mins

Technical data

Packaging
  Order No
Emulating indicator 4, 4 minutes 134°C, 250 pcs per case 504051000
Emulating indicator 5.3, 5.3 minutes 134°C, 250 pcs per case 504050800
Emulating indicator 7, 7 minutes 134°C, 250 pcs per case 504050900
Emulating indicator 18, 18 minutes 134°C, 250 pcs per case 504051400

Emulating Indicator (Adhesive) Steam

Clear color change from purple to green.

Overview

The OR staff is responsible for maintaining the integrity of the sterile field. Getinge Assured Emulating Indicators (Type 6) are the most advanced chemical indicators for monitoring the specific steam sterilization parameters of time, temperature and steam inside the pack and assures the user that maximum values for all cycle parameters have been achieved. 

Our Type 6 indicators have the highest precision available and require a full steam sterilization cycle to change color.

When a pack is opened, your OR staff can quickly verify that the conditions for sterilization were achieved and that the instruments and utensils are safe to use in surgical procedures.

This indicator is also self-adhesive which facilitates record-keeping.

* Not available for sales in the USA.

Self-adhesive for easier handling

Superior diagnostic ink technology

Lead free and no toxic heavy metals

Can be used as a permanent record

Consistent with EN ISO 11140-1 Type 6

Cycle specific calibrations – 134°C at 3.5, 4, 5.3 and 7 mins

Technical data

Packaging
  Order No
Emulating indicator 3.5 Adhesive, 3.5 minutes 134°C, 250 pcs per case 504051100
Emulating indicator 4 Adhesive, 4 minutes 134°C, 250 pcs per case 504052600
Emulating indicator 5.3 Adhesive, 5.3 minutes 134°C, 250 pcs per case 504051200
Emulating indicator 7 Adhesive, 7 minutes 134°C, 250 pcs per case 504051300

Pack Release for Low Temp

Multicritical Process Variable Indicator EO (Ethylene Oxide)

Clear color change from yellow to brown.

Overview

The Getinge Assured Multicritical Process Variable Indicator (Ethylene Oxide) is designed to be used in Ethylene Oxide (EO) gas sterilizers. 

When used as directed the indicator gives a visual confirmation that the items being sterilized have been subjected to the parameters of time, temperature, EO concentration and relative humidity according to EN ISO 11140-1, Type 4.

* Not available for sales in the USA.

Assurance to the user that minimum cycle parameters have been achieved inside the load

Can be used as a permanent record

Cost effective

Conforms to EN ISO 11140-1, Type 4

Technical data

Packaging
  Order No
Multicritical Process Variable Indicator EO (Ethylene Oxide), 250 pcs per bag 504051600

Multicritical Process Variable Indicator Formaldehyde

Clear color change from red to green.

Overview

The Getinge Assured Multicritical Process Variable Indicator (Formaldehyde) is designed to be used in low temperature steam/formaldehyde (LTSF) sterilizers. 

When used as directed the indicator gives a visual confirmation that the items being sterilized have been subjected to the following parameters of time, temperature and Formaldehyde concentration according to EN ISO 11140-1, Type 4.

* Not available for sales in the USA.

Assurance to the user that minimum cycle parameters have been achieved inside the load

Can be used as a permanent record

Cost effective

Conforms to EN ISO 11140-1, Type 4

Technical data

Packaging
  Order No
Multicritical Process Variable Indicator Formaldehyde, 250 pcs per case 504051900

Plasma Indicator

Clear color change from blue to pink.

Overview

The Getinge Assured Plasma Indicator gives visible confirmation that the pack has been exposed to hydrogen peroxide. When exposed to H2O2 sterilization process, the Plasma Indicator will change from blue to a shade of pink.

* Not available for sales in the USA.

Assurance to the user that the pack was exposed to hydrogen peroxide

Can be used as a permanent record

Cost effective

Designed to monitor plasma sterilizers/VHP/Hydrogen Peroxide Sterilizers

Technical data

Packaging
  Order No
Plasma Indicator, 250 pcs per case 504052000

Tape EO (Ethylene Oxide)

Tape for sterilization packages.

Overview

The Getinge Assured Tape (Ethylene Oxide) is designed for use in ethylene oxide (EO) sterilizers operating at 600 mg/l EO gas, 40-60% Relative Humidity, 54°C for 45 minutes or longer. The word "gas" turns green after exposure to an EO gas sterilization process, thus providing identification of processed items.

* Not available for sales in the USA.

For use in Ethylene Oxide sterilizers

Two widths, 18 mm and 24 mm

Color change from brown to green

EN ISO 11140-1, Type 1

Technical data

Packaging
  Order No
Tape 18mm Ethylene Oxide, 48 rolls per box 504053600
Tape 24mm Ethylene Oxide, 36 rolls per box 504053700
   

Pack Release for Dry Heat

Multicritical Process Variable Indicator Dry Heat

Clear color change from green to dark brown/black.

The Getinge Assured Multicritical Process Variable Indicator (Dry Heat)
is designed to be used in dry heat sterilizers.

When used as directed, the indicator gives visible confirmation that the goods were sufficiently exposed to dry heat sterilization conditions as specified by EN ISO 11140-1, Type 4.

* Not available for sales in the USA.

Assurance to the user that minimum cycle parameters have been achieved inside the load

Can be used as a permanent record

Cost effective

Conforms to EN ISO 11140-1, Type 4

Technical data

Packaging
  Order No
 Multicritical Process Variable indicator Dry Heat, 250 pcs per bag  504054800

Downloads